RS9110

RS9110

With the Pro-Series Wall Thermostats, contractors can offer owners easy, yet powerful and reliable control.

RS9210

With the Pro-Series Wall Thermostats, contractors can offer owners easy, yet powerful and reliable control.

RS9220

With the Pro-Series Wall Thermostats, contractors can offer owners easy, yet powerful and reliable control.

4040-001

A válvula solenoide Ranco® Série 4040 controla o fluxo de água para o umidificador para garantir que a umidade adequada seja fornecida, criando um ambiente mais confortável. A válvula solenoide 4040-001 tem uma tela de filtro para filtrar os contaminantes e eliminar o acúmulo no umidificador. O kit 4040-001 inclui uma conexão de compressão de entrada e uma ponteira para simplificar a instalação. A válvula solenoide controla o fluxo de água para o umidificador ligando e desligando o fluxo de água. Quando a válvula solenoide estiver fechada, ela cortará o fluxo de água para o umidificador. Quando a válvula for acionada, ela abrirá o fluxo de água para o umidificador. A válvula solenoide é controlada pelo umidistato.

K-78863-1

A Robertshaw® fabrica vários modelos diferentes de válvulas para lavadoras de roupas que foram criadas para uso como válvulas de mistura, incluindo válvulas operadas por piloto duplo em um corpo compacto comum. Seu projeto exclusivo de diafragma reduz a possibilidade de entrada de materiais estranhos na área da armadura. A bobina encapsulada em náilon dessas válvulas proporciona alta resistência mecânica e dielétrica e é resistente à umidade. Muitas válvulas são fornecidas com um tubo guia que elimina a corrosão e reduz o ruído para uma válvula mais silenciosa.

1950-002

The Robertshaw® 1950 and 1951 Series Thermopiles lead the industry for gas appliance applications. Their primary function is to ensure a standing pilot light is operative so that on a call for heat, the main burner gas will be properly ignited. Thermopiles are placed in gas applications to detect the existence of a flame for safety purposes by shutting off the potential gas flow to a burner. A thermopile is the assembly of many thermocouples to increase the millivolt output. Robertshaw thermopiles have two types of connections: coaxial and two-wire spade connectors. The 1950 Series Thermopiles, also known as TP-75, are two-wire spade connectors. The 1951 Series Thermopiles, also known as CP-2 (250 to 750 millivolts), are coaxial connectors. The 1950 and 1951 Series Thermopiles (pilot generators) are designed for use on self-powered gas control systems. They can be used to replace similar competitive devices. It includes PG9 Pilot Adaptor.

1950-018

The Robertshaw® 1950 and 1951 Series Thermopiles lead the industry for gas appliance applications. Their primary function is to ensure a standing pilot light is operative so that on a call for heat, the main burner gas will be properly ignited. Thermopiles are placed in gas applications to detect the existence of a flame for safety purposes by shutting off the potential gas flow to a burner. A thermopile is the assembly of many thermocouples to increase the millivolt output. Robertshaw thermopiles have two types of connections: coaxial and two-wire spade connectors. The 1950 Series Thermopiles, also known as TP-75, are two-wire spade connectors. The 1951 Series Thermopiles, also known as CP-2 (250 to 750 millivolts), are coaxial connectors. The 1950 and 1951 Series Thermopiles (pilot generators) are designed for use on self-powered gas control systems. They can be used to replace similar competitive devices. It includes PG9 Pilot Adaptor.

1950-518

The Robertshaw® 1950 and 1951 Series Thermopiles lead the industry for gas appliance applications. Their primary function is to ensure a standing pilot light is operative so that on a call for heat, the main burner gas will be properly ignited. Thermopiles are placed in gas applications to detect the existence of a flame for safety purposes by shutting off the potential gas flow to a burner. A thermopile is the assembly of many thermocouples to increase the millivolt output. Robertshaw thermopiles have two types of connections: coaxial and two-wire spade connectors. The 1950 Series Thermopiles, also known as TP-75, are two-wire spade connectors. The 1951 Series Thermopiles, also known as CP-2 (250 to 750 millivolts), are coaxial connectors. The 1950 and 1951 Series Thermopiles (pilot generators) are designed for use on self-powered gas control systems. They can be used to replace similar competitive devices. It includes PG9 Pilot Adaptor.

1950-532

The Robertshaw® 1950 and 1951 Series Thermopiles lead the industry for gas appliance applications. Their primary function is to ensure a standing pilot light is operative so that on a call for heat, the main burner gas will be properly ignited. Thermopiles are placed in gas applications to detect the existence of a flame for safety purposes by shutting off the potential gas flow to a burner. A thermopile is the assembly of many thermocouples to increase the millivolt output. Robertshaw thermopiles have two types of connections: coaxial and two-wire spade connectors. The 1950 Series Thermopiles, also known as TP-75, are two-wire spade connectors. The 1951 Series Thermopiles, also known as CP-2 (250 to 750 millivolts), are coaxial connectors. The 1950 and 1951 Series Thermopiles (pilot generators) are designed for use on self-powered gas control systems. They can be used to replace similar competitive devices. It includes PG9 Pilot Adaptor.
Rolar para o topo