TM-3

TM-3

The Skytech Wall Mounted Wired Timer features a 30/60/90 minute timer operation.

FP-45

The Robertshaw® FP-45 Antifreeze Valve uses a reliable, self-contained power element that is sensitive to temperature and operates without electrical power or sensors. In solar applications, the gate of the valve typically opens as temperatures decrease, allowing the liquid to spill and to be replaced by warmer water when the water is near the freezing point in solar panels. When warmer water enters, the gate of the valve is closed and the removal of water is interrupted.

AFV01100-02U

A Robertshaw® oferece bobinas de reparo para as válvulas de lavadoras de roupas modelo N-10 (CW-10 e CW-43) RC-120 e RC-240, os conjuntos de bobinas encapsuladas de reposição não devem ser usados com outros modelos. Essas bobinas estão disponíveis nos padrões 120V CA e 240V CA.

AFV01200-02U

A Robertshaw® oferece bobinas de reparo para as válvulas de lavadoras de roupas modelo N-10 (CW-10 e CW-43) RC-120 e RC-240, os conjuntos de bobinas encapsuladas de reposição não devem ser usados com outros modelos. Essas bobinas estão disponíveis nos padrões 120V CA e 240V CA.

AFV09100-02U

A Robertshaw® oferece bobinas de reparo para as válvulas de lavadoras de roupas modelo N-10 (CW-10 e CW-43) RC-120 e RC-240, os conjuntos de bobinas encapsuladas de reposição não devem ser usados com outros modelos. Essas bobinas estão disponíveis nos padrões 120V CA e 240V CA.

AFV09200-02U

A Robertshaw® oferece bobinas de reparo para as válvulas de lavadoras de roupas modelo N-10 (CW-10 e CW-43) RC-120 e RC-240, os conjuntos de bobinas encapsuladas de reposição não devem ser usados com outros modelos. Essas bobinas estão disponíveis nos padrões 120V CA e 240V CA.

613-NLU-0000-B

The Robertshaw® Mini-Tek Liquid Level Detector is used to detect the levels of liquids in major diesel engines. The Robertshaw Mini-Tek operates on the electrostatic or capacitance sensing principle. The probe portion of the unit, extending into the liquid, produces a change in electrical capacitance when liquid displaces the air immediately surrounding the probe. The Robertshaw Mini-Tek detector will provide warning when liquid levels reach approximately 50% of capacity. This provides time to take action before damage is done to the engine. The Robertshaw Mini-Tek comes in three different models. Model 613 Coolant Level Detector, Model 614 Hydraulic Oil or Fuel Detector, Model 624 Motor or Gear Fuel or Oil Detector.

K-76167-9

A válvula de água Robertshaw® série S-53 é uma válvula solenoide simples para máquinas de lavar louça e máquinas de gelo comerciais. A S-53 apresenta a combinação de projeto de um encaixe de entrada de latão ou encaixe de conexão rápida e um suporte de montagem, que permite a conexão direta ao encanamento de alimentação sem aplicar torque ao corpo da válvula.

RSW3

O Ranco Rocket RSW Hard Starts fornece um Rocket Boost ao seu compressor. O compressor do seu sistema de ar condicionado consome a maior parte da energia durante a partida. Durante o processo de inicialização, o compressor usa dez vezes mais energia do que durante o funcionamento. Isso faz com que o compressor consuma mais energia durante esse período, o que resulta em maior consumo de eletricidade. Um compressor pode dar partida mais de 6.000 vezes durante uma temporada normal de verão. Isso pode causar danos ao seu compressor e aos componentes elétricos do sistema de ar condicionado.
Rolar para o topo