712-008

712-008

The Robertshaw® 712 Series Intermittent Pilot Ignition System Kit features flame rectification with solid-state logic and flame sensing to provide automatic sequencing that will ensure proper operation of an intermittent pilot ignition device. The 712 pilot ignition systems are available with one of four different gas valve types to fit a wide range of furnace applications. Caution: Do not use on LP gas applications.

780-003

Das Robertshaw® Universal Ignition Control Uni-Kit® ist sowohl ohne Verriegelung (780-001) als auch mit Verriegelung (780-002) erhältlich. Das 780-003 ist ein Lockout mit einer Vorspülfunktion. Der Bausatz verfügt über einen Flammenfühlerschaltkreis, der automatisch das Vorhandensein eines Fernfühlers (2-Stab-System) erkennt, oder er schaltet auf lokale Erfassung (1-Stab-System) um, wobei die Zündflamme als Fühlerquelle verwendet wird. Wenn beide Systeme vorhanden sind, wird bei Ausfall eines Systems automatisch auf das andere umgeschaltet.

780-845

Die Robertshaw®-Heizflächenregler der Serie 780 sind für den Einsatz in gasbefeuerten Anlagen vorgesehen. Das System reagiert auf eine Wärmeanforderung durch einen Schalter oder Thermostat, um die Zündsteuerung mit Strom zu versorgen. Bei Modellen ohne Vorspülung wird der Zünder sofort eingeschaltet und bleibt für eine von zwei optional wählbaren Aufheizzeiten des Zünders eingeschaltet: ca. 17 oder 34 Sekunden. Bei Modellen mit Vorspüloption gibt es eine Verzögerung in Höhe der gewählten Aufheizzeit, bevor der Zünder eingeschaltet wird. Nach Ablauf der Aufheizzeit des Zünders wird das Gasventil geöffnet, um den Hauptbrenner mit Gas zu versorgen. Nach einigen Sekunden wird der Zünder ausgeschaltet und der Sensor aktiviert. Solange die Flamme erkannt wird, arbeitet das System weiter.

780-705

Die Robertshaw®-Direktzündungsregler der Serie 780 sind für gewerbliche Kochgeräte, gasbefeuerte Heizungen und Wassererwärmungssysteme vieler Arten geeignet. Das System reagiert auf eine Wärmeanforderung durch einen Schalter oder Thermostat, um das Gasventil zu öffnen. Gleichzeitig liefert die Zündsteuerung der Serie 780 einen Funken an die Elektrode, der das Gas zündet. Nach dem Anzünden des Gases prüft eine elektronische Schaltung das Vorhandensein einer Flamme durch Flammengleichrichtung. Wenn der Thermostat zufrieden ist, wird das Gasventil geschlossen, um das Gas des Hauptbrenners abzusperren.

780-715

The Robertshaw® 780 Series Pilot Controls feature flame rectification with solid-state logic and flame sensing to provide automatic sequencing that will ensure proper operation of an intermittent pilot ignition device. When the thermostat calls for heat, the 780 series control simultaneously initiates ignition sparking and opens the pilot valve portion of the gas valve. Pilot flame recognition stops ignition sparking and opens the main valve portion of the gas valve. Pilot burner flame is continuously monitored at a synchronous frequency for the duration of the heating cycle. Should the pilot flame fail during the heating cycle, the control will shut off the main valve until the pilot flame is established. The Robertshaw 780-845 lockout ignition control provides 90 seconds of spark, followed by a six minute time delay (purge) between ignition attempts. If the pilot flame is not sensed after three tries, the control goes into a one-hour lockout period. At the end of the lockout period, if the demand for heat is still present, the unit will repeat the three tries for ignition.

712-009

The Robertshaw® 712 Series Intermittent Pilot Ignition System Kit features flame rectification with solid-state logic and flame sensing to provide automatic sequencing that will ensure proper operation of an intermittent pilot ignition device. The 712 pilot ignition systems are available with one of four different gas valve types to fit a wide range of furnace applications. Caution: Do not use on LP gas applications.

780U-DS20

These 24V modules are highly configurable and replace over 700 part numbers, which simplifies inventory management. They come with up to 32 preloaded configurations, making installation easy. These modules are optimized for gas furnaces, water heaters, commercial cooking equipment, and unit heaters, ensuring seamless operation across a variety of replacement models.

780-735

The Robertshaw® 780 Series Pilot Controls feature flame rectification with solid-state logic and flame sensing to provide automatic sequencing that will ensure proper operation of an intermittent pilot ignition device. When the thermostat calls for heat, the 780 series control simultaneously initiates ignition sparking and opens the pilot valve portion of the gas valve. Pilot flame recognition stops ignition sparking and opens the main valve portion of the gas valve. Pilot burner flame is continuously monitored at a synchronous frequency for the duration of the heating cycle. Should the pilot flame fail during the heating cycle, the control will shut off the main valve until the pilot flame is established. The Robertshaw 780-845 lockout ignition control provides 90 seconds of spark, followed by a six minute time delay (purge) between ignition attempts. If the pilot flame is not sensed after three tries, the control goes into a one-hour lockout period. At the end of the lockout period, if the demand for heat is still present, the unit will repeat the three tries for ignition.

780U-HS30

These 24V modules are highly configurable and replace over 700 part numbers, which simplifies inventory management. They come with up to 32 preloaded configurations, making installation easy. These modules are optimized for gas furnaces, water heaters, commercial cooking equipment, and unit heaters, ensuring seamless operation across a variety of replacement models.